Cómo funciona y se conecta el Shelly Dimmer 0/1-10V PM Gen3

Shelly Dimmer 0/1-10V PM Gen3: how it works and how to connect it

The Shelly Dimmer 0/1-10V PM Gen3 (model S3DM-0010WW) doesn't dim bulbs: it dims drivers. That distinction is what decides whether it's for you or not.

It's the only Shelly dimmer with consumption measurement and with Matter as standard.

Two circuits, not one

Wiring diagram of the Shelly Dimmer 0/1-10V PM Gen3 with a dimmable LED driver

Here the power and the control go by separate paths:

  • The relay output (O) carries the 230 V to the driver.
  • The Dim+ and Dim− terminals carry the 0 to 10 V control signal.

Connect the Shelly's Dim+ to the driver's Dim+ and Dim− to Dim−: polarity matters. The S1 and S2 inputs accept a switch or push-buttons, in a one- or two-button configuration.

Why the relay isn't an extra

Difference between 0-10V and 1-10V dimming and why a relay is needed

Here's the detail that confuses a lot of people. In 1-10 V, the lowest possible signal is 1 V, and that value corresponds to minimum brightness, not off. No matter how far you turn the control down, the light stays on at around 10 %.

In 0-10 V most drivers do switch the output off when they reach 0 V, but not all guarantee it.

That's why this unit has a relay: it cuts the driver's power and achieves the real switch-off. A 0-10 V dimmer with no relay leaves the light on at minimum forever.

What you need to use it

A dimmable LED driver with a 0-10 V or 1-10 V input. You'll recognize it by two extra terminals marked Dim+ and Dim−, or 1-10V. If your fixture doesn't have them, this unit is no good for you.

You also need neutral at the installation point: unlike the Dimmer Gen3, this one doesn't work without it.

What sets it apart

  • Consumption measurement: voltage, current and active power in real time. It's the only Shelly dimmer that includes it.
  • Matter as standard, plus MQTT, REST and mJS scripting.
  • Configurable minimum and maximum brightness, to bound the driver's useful range.
  • Night mode and schedules with transitions.
  • Compatible with the Shelly Plus Add-on for sensors.

Frequently asked questions

Does it matter whether my driver is 0-10 V or 1-10 V?

The unit supports both. What changes is the behavior at minimum: with 1-10 V you rely on the relay to switch off.

My light doesn't fully switch off

Check that the relay output (O) is powering the driver. If you connected the driver directly to the line, bypassing the relay, you only have brightness control, not on/off.

The light behaves in reverse

Check the polarity of Dim+ and Dim−. Some drivers also allow reversing the signal from their own settings.

How many drivers can I connect?

It depends on the control current each one draws and the load the relay supports. Check your drivers' datasheet and don't size to the limit.

Is it good for 24 V LED strips?

Not directly. Strips are dimmed by PWM. It would only work if their power supply accepts a 0-10 V input.

And for normal bulbs?

No. For dimmable 230 V bulbs you need the Shelly Dimmer Gen3.

Related guides

Questions about your driver? Send us a photo of its label and we'll confirm whether it's compatible. Technical support in English.


Leave a comment

Please note, comments must be approved before they are published

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.